BD Angiocath™ Pheripheral IV Catheter
- Catheter made of radiopaque FEP Polymer.
- Catheter with thermo-moulded bevel ensures excellent penetration properties
- Triple-bevel needle
- Transparent clear flashback chamber
- Complete gauge range from 10G x 76 mm to 24G x 19 mm
- Available in longer lengths (14G and 16G available with 83 mm and 133 mm long catheters)
- BD Luer-Lok™ compatible
- Recommended uses: Infusion, Transfusion and Angiography
- Sterilization method is Ethylene Oxide
- CE marked
- Sterile, single use
- NB: Diameters 12G and 10G permit very large volume emergency infusions
BD Insyte™ and BD Insyte-N™ Peripheral IV Catheter with and without Wings
BD Insyte™
- Easy insertion
- The strength of BD Vialon™ makes it possible to manufacture a catheter with a finer, stronger, more reliable tip, giving it excellent penetration characteristics
- The catheter is rigid before insertion but becomes soft inside the body. This unique feature adds to the bio-compatibility of BD
- Vialon™ and results in a lower risk of complications
- Flow rate: BD Insyte™ is a thin-walled catheter with a higher flow rate than other catheters of the same gauge. BD Vialon™ has good kink resistance and kink recovery to ensure an optimum flow rate
- Recommended uses: Oncology, low venous pressure, fragile veins
BD Insyte-N™
- 14 mm long, the shortest on the market to accomodate small vein segments and provides a greater choice of insertion sites
- 24G for catheterization in every situation encountered in neonatology, paediatrics, oncology and geriatrics.
- BD Luer-Lok™ compatible
- Recommended uses: fragile veins, e.g. neonatology / low venous pressure
- Sterilization method is Ethylene Oxide
- Sterile, single use
- CE marked
- Manufactured in BD Vialon™, a unique polyurethane, radiopaque biocompatible catheter material
BD Insyte™ Autoguard™ / BD Insyte-N™ Autoguard™ Peripheral Safety IV Catheter
BD knows the importance to both clinician and patient of achieving first-stick success which is why we developed the BD Insyte™ Autoguard™ shielded IV catheter. BD Insyte™ Autoguard™ shielded IV catheters are designed to give you the satisfaction that comes from getting a successful first stick.
- Patented safety mechanism activation
- The push-button holds the needle unit in the extended position until the user activates the mechanism
- Pressing the push-button releases the spring so that the needle/flashback chamber retracts into the safety barrel.
- Luer Lock compatible
BD Insyte-N™ Autoguard™
- 14 mm long, the shortest on the market to accomodate small vein segments and provides a greater choice of insertion sites
- 24G for catheterisation in every situation encountered in neonatology, paediatrics, oncology and elderly patient
- Shorter length provides increased flow rates
- Available with or without wings
Recommended uses:
- fragile veins, e.g. neonatology
- low venous pressure
- Sterilization method is Ethylene Oxide
- Sterile, single use
- CE marked
BD Insyte™ Autoguard™ BC with Blood Control Technology
BD Insyte™ Autoguard™ BC is proven to reduce the risk of blood exposure by 95%.1
Reduce cross contamination risks
- Because there is dramatically less blood leakage, BD Insyte™ Autoguard™ BC can mean less
- potential cross contamination
- No spills means there’s no blood to get on gloves, clothing, shoes, bedding, floors, or equipment
Safe and clinically proven
- New blood-control technology proven to reduce the risk of blood exposure by 95%1
- Push-button shielding technology proven to reduce needlestick injuries by 95%2
- Greater first-stick success for difficult or compromised veins3
- Sterilization method is Ethylene Oxide
- Sterile, single use
- CE marked
- BD Vialon™ Biomaterial—softens up to 70% in the vessel, resulting in longer dwell times. Reduces the chance of mechanical phlebitis by up to 50%4, 5, 6,7
BD Neoflon™
- 24G and 26G PTFE catheter
- BD Neoflon™ is specially designed for the puncture of small fragile vessels, frequently encountered in paediatrics or elderly patients
- The unique design of the detachable wing holder makes the catheter easier to hold, using either a ported or nonported grip, despite its small size
- The flexible wings facilitate secure fixation, even on the hand or arm of the neonate without the need to immobilize the limb whilst at the same time reducing the risk of mechanical phlebitis
- Sterilization method is Ethylene Oxide
- Sterile, single use
- CE marked
BD Nexiva™
Closed IV Catheter System
- BD Nexiva™ closed IV Catheter System is a pre-assembled configurationwhich combines separate IV components into a single device
- It promotes greater efficiency and convenience with less handling time, and reduces the potential for blood leakage, helping to minimize clean-up
- Pre-attached extension tubing and soft wings reduce manipulation at the insertion site to help decrease the risk of mechanical phlebitis and irritation to the vein
Improved first-stick success
- With its compact size and shape, the BD Nexiva™ Closed IV Catheter System accommodates your preferred insertion technique
- BD Instaflash™ Needle Technology provides immediate visual confirmation of vessel entry along the cannula.
- These features increase the potential for a successful insertion
High Pressure Extension Set
- The pre-attached high pressure extension set is compatible with power injectors used with contrast- enhance CT scans*
- This preassembled system is designed to withstand pressures of up to a maximum of 300 PSI
BD Q-Syte™ Luer Access Split Septum
- A split septum needleless access system has 64%-70% lower CRBSI rates than mechanical valves1,2
- Patients are three times more likely, on average, to develop a CRBSI with the use of a mechanical valve versus a split septum needle-less access system1,2
Built in Stabilisation Platform
- The built in stabilisation platform is soft and flexible, and is designed to help minimise cannula movement in the vessel which may increase cannula dwell time.
- Sterilization method is Ethylene Oxide
- Sterile, single use
- CE marked
BD Nexiva™ Diffusics™
Closed IV Catheter System Radio-graphic Power Injection
- Now even smaller IV catheters gauge sizes (22 and 24G) can meet the needs of faster protocols
- Reduces the forces that can cause catheter motion in the vein1
- Significantly less impact to the vein during power injection2
- Helps protect clinicians from blood exposure during IV cannulation
- Sterilization method is Ethylene Oxide
- Sterile, single use
- CE marked
BD Saf-T-Intima™ Integrated Safety IV Catheter System
- BD Saf-T-Intima™ is equipped with a needle protection device that withdraws the needle into a safety barrel as soon as the needle is removed. This minimises the risk of accidental needle stick injuries
- BD Saf-T-Intima™ is fitted with a BD Luer-Lok™ connector for connection to any piece of equipment fitted with a Luer Adapter
- The BD Saf-T-Intima™ “Y” type adapter allows that the injection site can be used for bolus administration of medication
- Removable injection port
- Blood contact is avoided during insertion
- Sterilization method is Ethylene Oxide
- Sterile, single use
- CE marked
- Manufactured in BD Vialon™, a unique polyurethane, radiopaque biocompatible catheter material
BD Veca-C™ and BD Vecafix™ IV Dressing
- BD Veca-C™ and BD Vecafix™ are sterile IV dressings for optimum fixation of ported and non-ported IV catheters
- BD Veca-C™ and BD Vecafix™ protects the insertion site and allows the site to breathe
- The wound pad absorbs exudate at the insertion site, keeping the site dry
- A comfort pad, to be placed under the wings of the IV catheter, is included in the pack
- In addition, BD Veca-C™ has a transparent window of polyurethane that allows for visualization of phlebitis along the catheter track
- Sterilization method is Ethylene Oxide
- Sterile, single use
- CE marked
- The packing of the BD Veca-C™ dressing contains small amounts of latex. The product itself however, is latex free
BD Venflon™ Peripheral IV Catheter with Injection Valve
- BD Venflon™ intravenous catheter with integrated injection port and valve for peripheral catheterisation
- Permits needle-free administration of bolus medications during infusion
- Back-cut needle bevel and tapered end of the PTFE catheter allows easier insertion and minimizes the risks of vein damage
- Wing position reduces the risk of bacterial contamination by preventing any direct contact between the rear of the catheter hub and the skin. Utilizing the wings, immobility of the catheter can be further ensured by the application of the BD Veca-C™ and BD
- Vecafix™ IV dressing
- BD Luer-Lok™ compatible
- Sterilization method is Ethylene Oxide
- Sterile, single use
- CE marked
BD Venflon™ Pro Peripheral IV Catheter with Injection Valve
- The improved design of the injection port cap ensures easy opening and secure closing, whilst avoiding touch contamination of the injection port and valve
- Improved insertion characteristics as BD Vialon™ make it possible to manufacture a catheter with a better tapered, stronger and more reliable tip geometry which improves the chances of a first cannulation attempt success and also reduces the risk of thrombophlebitis
- Although the catheter material is rigid before insertion, the qualities of BD Vialon™ allow for softening of the catheter material once it is inside the body, again reducing the risk of thrombophlebitis
- There is an improved flow rate when compared with FEP polymer catheters as BD Vialon™ allows for a larger internal diameter
- BD Luer-Lok™ compatible
- Sterilization method is Radiation
- Sterile, single use
- CE marked
- Manufactured in BD Vialon™, a unique polyurethane, radiopaque biocompatible catheter material
BD Venflon™ Pro Safety Peripheral Safety IV Catheter with Injection Valve
- BD Venflon™ Pro Safety needle protected IV Cannula combines all the advantages of the original
- BD Venflon™ Pro, with second generation safety protection features against needlestick injuries.
- Familiar ported design with ‘snap-cap’ aids non-touch technique which helps prevent port being inadvertently left open
- Sharp needle technology provides both ease of penetration and improved patient comfort
- Flexible wings stabilize the cannula in the vein and provide comfortable securement for the patient
- BD Venflon™ Pro Safety is designed for use in all departments and provides a full range of features to suit most clinical indications
- Grip is ergonomically designed to allow for a variety of user techniques and to aid insertion
Needle shield
- Once activated, the needle tip is fully encapsulated inside the protection mechanism, which is designed to minimise the risk of scratching yourself
- The unique design captures residual blood safely within the device, thereby minimizing the risk of unanticipated blood splatter during and after activation
- With needle safely encased in smooth edged plastic shield
- Sterilization method is Radiation
- Sterile, single use
- CE marked
Manufactured in BD Vialon™, a unique polyurethane, radiopaque biocompatible catheter material
Obturator
- The Obturator protects the inner lumen of the catheter from coagulation and thrombus formation after discontinuation of infusion
- The Obturator is color coded to match the corresponding catheter gauge
- Sterilization method is Ethylene Oxide
- Sterile, single use
- CE marked